Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Rapid and Reliable HPLC Method for the Determination of Vitamin C in Pharmaceutical Samples

Snezana S Mitić1, Danijela A Kostić1 , Danijela C Nasković-Đokić2, Milan N Mitic1

1Department of Chemistry, Faculty of Natural Sciences and Mathematics,Visegradska 33, 18000 Niš; 2D.D. ''Zdravlje-Actavis"- Pharmaceutical and Chemical Company, 16000 Leskovac, Serbia.

For correspondence:-  Danijela Kostić   Email: danijelaakostic@yahoo.com   Tel:+38118533014

Received: 2 July 2010        Accepted: 24 November 2010        Published: 14 February 2011

Citation: Mitić SS, Kostić DA, Nasković-Đokić DC, Mitic MN. Rapid and Reliable HPLC Method for the Determination of Vitamin C in Pharmaceutical Samples. Trop J Pharm Res 2011; 10(1):105-111 doi: 10.4314/tjpr.v10i1.16

© 2011 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop and validate an accurate, sensitive and reproducible high performance liquid chromatographic (HPLC) method for the quantitation of vitamin C in pharmaceutical samples.
Method: The drug and the standard were eluted from Superspher RP-18 (250 mm x 4.6 mm, 10mm particle size) at 20 0C. The mobile phase was prepared by carefully adding acetic acid (500 ml) to 1.5g of 1-hexanesulfonic acid sodium salt  and  mixing well (pH 2.6). The flow rate was 0.7 mL min-1. UV detector, set at 280 nm, was used to monitor the effluent.
Results: Each analysis required no longer than 4 min. The limit of quantitation was 1.95 mg mL-1. Recovery (%) for different concentrations ranged from 99.58 to 101.93.
Conclusion: The simplicity of this low-cost, rapid technique and its high specificity to ascorbic acid, even in the presence of a variety of excipients, demonstrate that this HPLC method would be particularly suitable for the determination of ascorbic acid in the investigated preparations as well as other similar pharmaceutical/veterinary formulations without prior sample preparation.

Keywords: Ascorbic acid; Pharmaceutical preparations; HPLC method

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates